How to turn off SCR ?
The gate current can turn on SCR but once turned on, the gate loses control. Even if we reduce the gate current to zero, SCR continues to conduct. We can turn off a conducting SCR by :
- Reducing its anode current below the holding current for a minimum specified time.
- Applying a reverse voltage across the SCR.
The experimental setup for plotting SCR characteristics is as shown in Figure.