Reasons for Developing Electrical and Magnetic Fault.
Q.Give the reasons for developing electrical and magnetic fault.
Sr. No. |
Faults |
Reason |
Remedial measures |
1 |
Wrong electric connections |
Field winding connections may be |
Check the connection. Check direction |
2 |
Contact, connections opening. |
Dry soldering, improper and loose soldering |
Resolder the joints etc. clean the |
3 |
Damaged Insulation |
Over voltage stresses, long running, |
Dry the insulation. Check voltage, reduce |
4 |
Commutator darkning, Burning |
Due to dirt/ Dust accumulation. Offering |
Clean the commutator. Adjust and check |
Sr. No. |
Faults |
Reasons |
Remedial Measure |
1. |
Misalignment of poles |
Due to mechanical injuries, blows, wrong storage of machine sometimes |
Necessary alignment should be done be. Nut-bolt fitting should be |
2. |
Loose Poles |
Due to excessive vibration created by abnormal speed, loose foundation |
Steps be taken to correct the position and make tight fitting of |
3. |
Non-uniform air-gap |
If rotating part is not true then it creates a non uniform air-gap. |
Make true the shaft of rotor or replace it. |
4. |
Abnormal heating of core. |
Magnetic losses increase if there is gap between stamping of core, |
Tighten the core stampings Adjust the voltage to its normal voltage, |
5. |
Warped and dented core and burns. |
At some spots the insulation on the core is burnt, causes sharp rise |
Necessary repairs, rewarnishing core. Replacing same stampings and |