Reasons for Developing Electrical and Magnetic Fault
Sr. No. |
Fault |
Reasons |
Remedial measures |
1 |
Wrong electric connections |
Field winding connections may be wrong. Field-Armature winding |
Check the connection. Check direction of rotation. Interchange |
2 |
Contact, connections opening. |
Dry solding, improper and loose soldering of joints. Melting of |
Resolder the joints etc. Clean the contact. Dry soldered joints be |
3 |
Damaged Insulation |
Over voltage stresses, long running, over loading, entry of moisture. |
Dry the insulation. Check voltage, reduce load. Stop the machine |
4 |
Commutator darkning, Burning |
Due to dirt / Dust accumulation offering low resistance path to the |
Clean the commutator.Adjust and check brush tension.Replace shape |
Sr.no. |
Fault |
Reasons |
Remedial |
1 |
Mialsalignment of poles. |
Due to mechanical injuries, blows, wrong storage of machine sometimes |
Necessary alignment should be done. Nut-bolt fitting should be |
2 |
Loose poles. |
Due to excessive vibration created by abnormal speed, loose |
Steps be taken to correct the position and make tight fitting of |
3 |
Non-uniform air-gap |
If rotating path is not true then it create a non uniform air-gap. |
Tighten the core stampings. adjust the voltage to its normal voltage, |
4 |
Abnormal heating of core |
Magnetic looses increase if there is gap between stamping of core, |
Tighten the core stampings. Adjust the voltage to its normal voltage, |
5 |
Warped and dented core and burns. |
At some spots the insulation on the core is burnt, causes sharp rise |
Necessary repairs rewarnishing core. Replacing same stampings. |