Induced Over Voltage Withstand Test of Transformer

Induced over-voltage withstand test This test is routine test i.e. it is carried on all the transformers. Before commissioning the transformer it is necessary to know that the insulation resistance of a transformer is greater than a specified value, to avoid excessive leakage currents. Megger test for insulation are carried out between windings, between winding … Read more

MCB breaker VS Fuse, Difference between Fuse and MCB in Details

FUSE In electronics and electrical engineering, a fuse is an electrical safety device that operates to provide overcurrent protection of an electrical circuit. Its essential component is a metal wire or strip that melts when too much current flows through it, thereby stopping or interrupting the current. It is a sacrificial device; once a fuse … Read more

Separate Source Voltage Withstand Test of Transformer

Separate source voltage withstand test of Transformer (Power frequency) Q. Explain with neat sketch power frequency high voltage test on transformer. Before commissioning the transformer it is necessary to know that the insulation resistance of a transformer is greater than a specified value, to avoid excessive leakage currents. Megger test for insulation are carried out … Read more

Impulse Test of Transformer, Measurement of Insulation Resistance of Transformer

Impulse Test of Transformer Q. State how insulation resistance of a transformer is measured. Measurement of Insulation Resistance of Transformer Before commissioning the transformer it is necessary to know that the insulation resistance of a transformer is greater than a specified value, to avoid excessive leakage currents. Megger test for insulation are carried out between … Read more

Working of Inverter, House Inverter का Wiring Connection कैसे करना है, Wiring of Inverter

Working of Inverter Inverters convert DC Power into AC Power. An inverter is used to produce an un-interrupted 220V AC or 110V AC (depending on the line voltage of the particular country) supply to the device connected as the load at the output socket. The inverter gives constant AC voltage at its output socket when … Read more

Sumpner’s Test, Back to Back for two identical 1-phase Transformers, Regenerative Test of Transformer

Sumpner’s Test Back to Back (Sumpner’s Test) (for two identical 1-phase Transformers) (Regenerative Test) Q. Explain the procedure for back to back test on transformer with neat circuit diagram. State advantages and disadvantages of this method. Q. Draw the experimental setup of the Sumpners test and state its advantage. Q. Draw the experimental set up … Read more

Ideal Transformer Diagram Properties Working and Phasor Diagram

Ideal Transformer The ideal transformer has following properties. Negligible current for establishing flux in the core. There is no magnetic leakage. Windings have no ohmic resistance. So resistance of primary and secondary winding is zero. Consider an ideal transformer shown in Figure. The primary is connected to ac supply of V1 volt and secondary is kept … Read more

Conditions to be Satisfied for Parallel Operation of Transformers

Parallel Operation of Transformer Q. What is the need of parallel operation of transformers? Discuss the conditions to be satisfied before connecting two 1-phase transformer in parallel. When the load current increases above the capacity of one transformer, we can connect one more in parallel instead of replacing the existing transformer with a bigger one. … Read more

Parallel Operation of Transformer, Why Transformer Use in Parallel

Parallel Operation of Transformer Q. What is the need of parallel operation of transformers? Discuss the conditions to be satisfied before connecting two 1-phase transformer in parallel. When the load current increases above the capacity of one transformer, we can connect one more in parallel instead of replacing the existing transformer with a bigger one. … Read more