Electrical MCQ’s
Electrical MCQ’s questions & answer Questions 51 to 57 Questions 41 to 50 Questions 31 to 40 Questions 21 to 30 Questions 11 to 20 Questions 01 to 10
Electrical MCQ’s questions & answer Questions 51 to 57 Questions 41 to 50 Questions 31 to 40 Questions 21 to 30 Questions 11 to 20 Questions 01 to 10
Circuit Diagram for Performing Load Test on 415 V, 3 Phase, 4.8A, 3HP, Delta Connected sq. Cage Induction Motor Q. Draw a neat circuit diagram for performing load test on 415 V, 3Φ, 4.8A, 3HP, Delta connected sq. cage induction motor. Specify the meter ratings.
Causes of Motor Suffers from Heavy Vibrations and Excessive Noise when Operating Q. What are the probable causes, if the motor suffers from heavy vibrations and excessive noise when operating ? The induction motor’s performance is affected by the harmonics in the time variations of the impressed voltage. Air-gap flux harmonics are produced due to … Read more
Causes of Failure of Underground Cables Q. What are the causes of failure of underground cables ? 1. Mechanical Failure : The various Layers like sheath, conductor, Insulation a be injured. Due to injuries the cable may fail to work. Causes may be due to (A) Accidents (B) Carelessness … Read more
Advantages of Phase Balancing Following are the main advantages of phase balancing : Due to phase balancing the load is uniformly and almost equally distributed on all the three phases of the system. Due to imbalance, feeder capacity is not property utilized hence balancing makes proper utilization of feeder capacity. Current balancing procedure will remove … Read more
Need of Energy Conservation in Transformer Q. State the need of energy conservation in transformer. Transformer is a vital power equipment in a power system, which plays significant role in generation transmission and distribution of electrical energy. Transformer operating efficiency directly affects the costs and benefits of the whole power system. In a typical power … Read more
Reasons for Developing Electrical and Magnetic Fault Q. Give the reasons for developing electrical and magnetic fault. Electrical Faults : Sr. No. Fault Reasons Remedial measures 1 Wrong electric connections Field winding connections may be wrong. Field-Armature winding connections might be wrong. 3-phase motor phase sequence connection R-Y-B may be wrong. Check the connection. Check … Read more
External Causes of Failure and Abnormal Operation of Equipments Q. What are the external causes of failure and abnormal operation of equipments. External Causes : A 3 – phase machine is supplied with 3-line wires L1 L2 L3. These are called as lines. If the fault is developed in the feeder / Distributor line only two lines will … Read more
Transformer Energy Conservation Method After selection of a transformer, adopt a transformer economic operation scheme to arrange operations, make the transformer operate in economic operation interval, economic switching of transformer between each operation mode and economic dispatch between transformer loads, etc. Adopting these schemes can improve transformer operating efficiency and reduce its operation on achieve … Read more
External Causes of Failure of Equipment Q. State external causes of failure of equipment. These causes are external to the machine from supply to the terminal box of the machine. A 3 – phase machine is supplied with 3-line wires L1, L2, L3. These are called as lines. If the fault is developed in the … Read more